ipmi_ui(1)             Crude interface to an IPMI system            ipmi_ui(1)

NAME
       ipmi_ui - Crude interface to an IPMI system

SYNOPSIS
       ipmiui [-dmsg] [-dmem] [-c] connection-1[connection-2]

       The connections are specified as either:

       smi smi-num

       or

       lan IP-addr port [IP-addr-2 port-2] auth privilege username password

DESCRIPTION
       The  ipmi_ui  program  connects to an IPMI system, and allows access to
       IPMI entities and sensors and OpenIPMI controls.   It's  rather  crude,
       and  primarily for testing OpenIPMI, but it has some use beyond that so
       it is provided.

       Normally, ipmi_ui starts up in a full-screen format.  The  left  window
       shows  the  output  of  commands,  the right window shows the logs from
       OpenIPMI.  Both windows are scrollable with page up and page down keys,
       press the "F1" key to choose the the left window to  scroll,  the  "F2"
       key to choose the right window to scroll.

       Note that you must set your environment TERM variable properly for your
       terminal, or ipmi_ui will display garbage on the screen.

       Note  that  you  can  put  two connection specifications on the command
       line, and ipmi_ui will make two connection.  You can only  do  this  if
       the  connections  are to the same IPMI domain through different manage-
       ment controllers.  Also, each LAN connection may have two IP addresses.
       These are two different addresses to the  same  management  controller.
       So  you  may have a total of 4 IP addresses to an IPMI domain, two man-
       agement controllers and two IP adresses to each management controller.

OPTIONS
       -dmsg  Turn on message debugging, this will dump all  messages  to  the
              log window.

       -dmem  Turn  on memory debugging, this will cause memory allocation and
              deallocations to be checked.  When the  program  terminates,  it
              will dump all memory that was not properly freed (leaked).

       -snmp  Enable  the  SNMP  trap  handler.  ipmi_ui must be compiled with
              SNMP code enabled for this option to be available.

       -c     Run the program  in  command-line  mode.   This  is  useful  for
              scripting.  All output goes to standard output, there is no win-
              dowing.

       smi-num
              The SMI number to connect to, for systems with more than on sys-
              tem interface.  Generally, this is '0'.

       IP-addr
              The IP address of the LAN interface.

       port   The UDP port of the LAN interface, general 623.

       IP-addr-2
              Some systems support multiple IP connections, this specified the
              second address and is optional.  If specified, OpenIPMI will use
              both  IP  addresses  and  fail over to the working one if one of
              them fails.

       port-2 The port for the second IP connection, generally 623.

       auth   The authorization to use  for  the  connection,  either  "none",
              "straight", "md5", or "md2".

       privilege
              The  privilege  to  use  for  the connection, either "callback",
              "user", "operator", or "admin".  Note that some IPMI  operations
              will fail without the correct privilege.

       username
              The  user  name to use for the connection.  If using this anony-
              mous user, this should be the empty string "".

       password
              The password to use for the connection.

ENTITIES
       Entities are listed by their entity id (the type of  entity  they  are)
       and  their  entity instance.  Entities may be active or inactive in the
       system, the standard IPMI algorithm for determining this is used.  Com-
       mands on entities are:

       entities
              List all the entities in the system.  The output is  the  entity
              specifier,  followed  by an optional entity name in parenthesis,
              followed by "present" or "not present".

       check_presence
              For the check of presence for all entities.

       fru entity
              List the FRU information associated with the entity.

       dump_fru is_logical device_address device_id lun private_bus channel
              Dump raw information from the specified FRU device.

SENSORS
       Sensors define input devices that OpenIPMI can monitor.

       sensors entity
              List all the sensors that monitor the given entity.  The  output
              is  the  sensor  specifier (the entity specifier followed by the
              sensor name, with spaces converted to ~). followed by the sensor
              name.

       sensor sensor
              Pull up the given sensor and display all  its  information.   In
              full-screen mode, the sensor will be re-queried every second.

       rearm global [assertion-mask deassertion-mask]
              Rearm  the  given sensor.  If global is 1, then the whole sensor
              is rearmed.  If global is 0, then  the  assertion-mask  and  de-
              assertion-mask  must  be  specified  telling which thresholds or
              states to rearm.

       events_enable events scanning assertion-bitmask deassertion-bitmask
              Enable or disable events for the  given  sensor.   events  turns
              events on or off from the sensor (0 or 1).  scanning turns scan-
              ning on or off for the sensor (0 or 1).  assertion-bitmask spec-
              ifies the bitmask of thresholds or states that should be enabled
              or disabled when a thrshold or state is asserted.  It is a bunch
              of  0's  and  1's, where the first one is for threshold/state 0,
              the second  for  threshold/state  1,  etc.   deassertion-bitmask
              specifies the bitmask of thresholds or states that should be en-
              abled or disabled when a thrshold or state is deasserted.

CONTROLS
       Controls  are  output devices that can control things like LEDs, power,
       reset lines and such.

       controls entity
              List all the controls that control the given entity.  The output
              is the control specifier (the entity specifier followed  by  the
              control  name, with spaces converted to ~). followed by the con-
              trol name.

       control control
              Pull up the given control and display it's current state.

       set_control val1 [val2 ...]
              Change the value of a control.  Note that for controls with mul-
              tiple values, every value must be specified.

EVENTS
       Events are asynchronous messages from sensors that tell the user that a
       sensor has done something.  Events are generally  stored  in  a  system
       event  log  (SEL);  OpenIPMI will fetch the events from the SELs in the
       system.

       Since multiple SELs may exist, an event is specified by the MC it  came
       from  in  the  format  "(channel addr)" and a log number.  The same log
       number may exist in multiple MCs.

       Events are displayed in the log window as they come in.  If they can be
       correlated with a sensor, they will be display with as much information
       as possible.

       delevent channel mc-addr log-num
              Delete the given event.  Note that many SELs do not support  in-
              dividual  deletes, so this may only delete the local copy of the
              event, not the one in the SEL.  In this case, to  delete  events
              in  the  SEL, you must delete all the events in the SEL and wait
              about 10 seconds for OpenIPMI to do a full SEL clear.

       clear_sel
              Delete all events in the SEL.  This process may take some  time,
              so if you do this and quit immediately it may not be complete.

       list_sel
              List all events in the local copy of the SELs.  This is only the
              local  copy, if the copies in the actual have change, this won't
              be reflected.

       get_sel_time channel mc-num
              Get the time in the SEL for the given MC.

MANAGMENT CONTROLLERS (MCs)
       In OpenIPMI, you normally don't deal with management controllers.  They
       are considered internal to the system.  However, for debugging,  infor-
       mation about them is provided.

       mcs    List all the MCs in the system and whether they are active.  MCs
              are displayed in the format "(channel address)".

       mc channel mc-addr
              Display  a  boatload  of information about the MC, mostly coming
              from the get device id command.

       mccmd channel mc-addr LUN NetFN Cmd [data ...]
              Send an IPMI command to the given MC.  The MC must exist and  be
              active to do this.

       mc_reset channel mc-addr [warm | cold]
              Send  a  warm or cold reset command to the given MC.  The action
              the MC takes is system-specific.

       scan channel mc-addr
              Scan for an MC at the given  address.   If  the  MC  exists  but
              OpenIPMI  didn't  know about it, it will be added.  If the MC no
              longer exists, then it will be removed.

       mc_events_enable channel mc-num enabled
              Enable or disable event generation for the given MC.

       mc_events_enabled channel mc-num
              Prints out if the events are enabled for the given MC.

LAN Parameter Configuration
       OpenIPMI has functions that make it easier to configure the LAN parame-
       ters of a LAN connection.  Note that the LAN  parameters  have  a  lock
       that  OpenIPMI  attempts  to use.  If you read the LAN parameters, they
       will be locked until you either write them or clear the lock.

       readlanparm channel mc-num channel
              Read lanparm information from an MC and display it in  the  dis-
              play window.

       viewlanparm
              Show current lanparm information in the display window.

       writelanparm channel mc-num channel
              Write  the current LANPARM information to an MC.  Note that this
              must be the MC that the parameters were read from.

       clearlanparmlock [channel mc-num channel]
              Clear a LANPARM lock.  If the MC is given, then the LANPARM lock
              is directly cleared.  If not given, then the  LANPARM  lock  for
              the current parms is cleared.

       setlanparm config [selector] value
              Set  the  given config item to the value.  The optional selector
              is used for items that take a selector, like "auth"  or  any  of
              the items in "destination".

Platform Event Filter (PEF)
       OpenIPMI  contains  function  to help manage the PEF settings on a BMC.
       Note that the PEF parameters have a lock that OpenIPMI attempts to use.
       If you read the PEF parameters, they will be locked  until  you  either
       write them or clear the lock.

       readpef channel mc-num
              Read the PEF information from an MC.

       clearpeflock [channel mc-num]
              Clear a PEF lock.  If the MC is given, then the PEF lock on that
              MC  is  directly  cleared.   If no MC is given, then the current
              PEF's lock is cleared.

       viewpef
              Show current pef information in the display window.

       writepef channel mc-num
              Write the current PEF information to an MC.

       setpef config [selector] value
              Set the given config item to the value.  The  optional  selector
              is  used  for  items  that take a selector, like anything in the
              event filters, alert policies, or alert strings.

       pet connection channel ip-addr mac_addr eft-selector policy-num apt-se-
       lector lan-dest-selector
              Set up the connection for the domain to send PET traps from  the
              given  connection  to  the  given  IP/MAC address over the given
              channel.  This does all the LAN and PEF  configuration  required
              to configure a system to send event traps.

CONNECTIONS
       OpenIPMI can maintain multiple connections to a single domain.  It will
       generally only use one of these at a time (although the other will con-
       stantly  be  under  test).   This  is the "active" connection.  You can
       query and set which connection is active.

       The connection number is the connection from the command line.  You can
       specify two connections on the command line (the  part  beginning  with
       "lan",  "smi",  etc.).   The first connection you specify is connection
       zero, the second is connection 1.

       is_con_active connection
              Print out if the given connection is active or not.

       activate_con connection
              Activate the given connection.

OTHER COMMANDS
       msg channel IPMB-addr LUN NetFN Cmd [data ...]
              Send an IPMI command to the given IPMB address.  This is  avail-
              able in case the given MC cannot be found or enabled.

       sdrs channel mc-addr do-sensors
              Dump  all  the  sdrs  from the given MC.  If do-sensors is true,
              then dump the device SDR.  If it is false,  dump  the  main  SDR
              repository on the MC.

       scan channel IPMB-addr
              Perform an IPMB bus scan for the given IPMB, to try to detect an
              MC  at  the  given address.  IPMB bus scanning can be slow, this
              can help speed things up if you already know the address.

       quit   Leave the program.

       reconnect
              Attempt to disconnect and  reconnect  to  the  IPMI  controller.
              This is primarily for testing.

       display_win
              Set the display window (left window) for scrolling, just in case
              the "F1" key doesn't work.

       log_win
              Set  the  log  window (right window) for scrolling, just in case
              the "F2" key doesn't work.

       help   Dump some terse help output about all the commands.

ERROR OUTPUT
       All error output goes to the log window.

SEE ALSO
       ipmilan(8)

KNOWN PROBLEMS
       Our name is legion.

AUTHOR
       Corey Minyard <cminyard@mvista.com>

OpenIPMI                           05/13/03                         ipmi_ui(1)