NAME
       thermal-conf.xml - Configuration file for thermal daemon

SYNOPSIS
       $(TDCONFDIR)/etc/thermald/thermal-conf.xml

DESCRIPTION
       thermal-conf.xml  is a configuration file for the thermal daemon. It is
       used to configure thermal sensors, zone and cooling devices. The  loca-
       tion of this file depends on the configuration option used during build
       time.

       The  terminology  used in this file conforms to "Advanced Configuration
       and Power Interface Specification". The ACPI  thermal  model  is  based
       around conceptual platform regions called thermal zones that physically
       contain  devices, thermal sensors, and cooling controls. For example of
       a thermal zone can be a CPU or a laptop cover. A zone can contain  mul-
       tiple sensors for monitoring temperature. A cooling device provides in-
       terface  to reduce the temperature of a source device, which causes in-
       crease in the temperature. An example of a cooling device is a  FAN  or
       some Linux driver which can throttle the source device.

       A  thermal  zone configuration includes one or more trip points. A trip
       point is a temperature at which a cooling device needs to be activated.

       A cooling device can be either active or passive. An example of an  ac-
       tive  device is a FAN, which will not reduce performance at the cost of
       consuming more power and  noise.  A  passive  device  uses  performance
       throttling  to  control  temperature.  In  addition  to cooling devices
       present in the thermal sysfs, the following cooling devices  are  built
       into the thermald, which can be used as valid cooling device type:

       • rapl_controller

       • intel_pstate

       • cpufreq

       • LCD

       The  thermal  sysfs  under Linux (/sys/class/thermal) provides a way to
       represent per platform ACPI configuration. The kernel thermal  governor
       uses  this  data to keep the platform thermals under control. But there
       are some limitations, which thermald tries to resolve. For example:

       • If the ACPI data is not optimized or buggy.  In  this  case  thermal-
         conf.xml can be used to correct the behavior without change in BIOS.

       • There may be thermal zones exposed by the thermal sysfs without asso-
         ciated  cooling actions. In this case thermal conf.xml can be used to
         tie the cooling devices to those zones.

       • The best cooling method may not be in the thermal sysfs. In this case
         thermal-conf.xml can be used to bind a zone to  an  external  cooling
         device.

       • Specify  thermal  relationships. A zone can be influenced by multiple
         source devices with varying degrees. In  this  case  thermal-conf.xml
         can be used to define the relative influence for apply compensation.

FILE FORMAT
       The  configuration file format conforms to XML specifications. A set of
       tags defined to define platform, sensors, zones,  cooling  devices  and
       trip points.

       <ThermalConfiguration>
         <Platform>
           <Name>Example Platform Name</Name>
           <!-- UUID is optional, if present this will be matched. Both product
                name and UUID can contain wild card "*", which matches any
                platform. -->
           <UUID>Example UUID</UUID>
           <!-- configuration file format conforms to XML specifications. A
                set of tags defined to define platform, sensors, zones, cooling
                devices and trip points. -->
           <ProductName>Example Product Name</ProductName>
           <Preference>QUIET|PERFORMANCE</Preference>
           <!-- Quiet mode will only use passive cooling device. "PERFORMANCE"
                will only select active devices. -->
           <ThermalSensors>
             <ThermalSensor>
               <!-- New Sensor with a type and path -->
               <Type>example_sensor_1</Type>
               <Path>/some_path</Path>
               <AsyncCapable>0</AsyncCapable>
             </ThermalSensor>
             <ThermalSensor>
               <!-- Already present in thermal sysfs, enable this or
                    add/change config For example, here we are indicating
                    that sensor can do async events to avoid polling. -->
               <Type>example_thermal_sysfs_sensor</Type>
               <!-- If async capable, then we don't need to poll. -->
               <AsyncCapable>1</AsyncCapable>
             </ThermalSensor>
           </ThermalSensors>
           <ThermalZones>
             <ThermalZone>
               <Type>Example Zone type</Type>
               <TripPoints>
                 <TripPoint>
                   <SensorType>example_sensor_1</SensorType>
                   <!-- Temperature at which to take action. -->
                   <Temperature> 75000 </Temperature>
                   <!-- max/passive/active If a MAX type is specified, then
                        daemon will use PID control to aggressively throttle
                        to avoid reaching this temp. -->
                   <type>max</type>
                   <!-- SEQUENTIAL | PARALLEL. When a trip point temp is
                        violated, then number of cooling devices can be
                        activated. If control type is SEQUENTIAL then, it
                        will exhaust first cooling device
                        before trying next. -->
                   <ControlType>SEQUENTIAL</ControlType>
                   <CoolingDevice>
                     <index>1</index>
                     <type>example_cooling_device</type>
                     <!-- Influence will be used order cooling devices. First
                          cooling device will be used, which has highest
                          influence. -->
                     <influence> 100 </influence>
                     <!-- Delay in using this cdev, this takes some time too
                          actually cool a zone. -->
                     <SamplingPeriod> 12 </SamplingPeriod>
                     <!-- Set a specific state of this cooling device when this
                          trip is violated. -->
                     <TargetState> 6 </TargetState>
                   </CoolingDevice>
                 </TripPoint>
               </TripPoints>
             </ThermalZone>
           </ThermalZones>
           <CoolingDevices>
             <CoolingDevice>
               <!-- Cooling device can be specified by a type and optionally
                    a sysfs path. If the type is already present in thermal
                    sysfs, there is no need of a path. Compensation can use
                    min/max and step size to increasing cool the system.
                    Debounce period can be used to force a waiting period
                    for action. -->
               <Type>example_cooling_device</Type>
               <MinState>0</MinState>
               <IncDecStep>10</IncDecStep>
               <ReadBack> 0 </ReadBack>
               <MaxState>50</MaxState>
               <DebouncePeriod>5000</DebouncePeriod>
               <!-- If there are no PID parameters, compensation increase step
                    wise and exponentially (if single step is not able to
                    change trend).
                    Alternatively a PID parameters can be specified then next
                    step will use PID calculation using provided PID
                    constants. -->
               <PidControl>
                 <kp>0.001</kp>
                 <kd>0.0001</kd>
                 <ki>0.0001</ki>
               </PidControl>
               <!-- Write some prefix attached to state value, like below the
                    prefix is "level ". It will preserve spaces as entered
                    when writing to sysfs. -->
               <WritePrefix>level </WritePrefix>
             </CoolingDevice>
           </CoolingDevices>
         </Platform>
       </ThermalConfiguration>

EXAMPLE CONFIGURATIONS
       Example  1:  This is a very simple configuration, to change the passive
       limit on the CPU. Instead of default, this new temperature 86C  in  the
       configuration  is  used.  This will start cooling, once the temperature
       reaches 86C.

       <?xml version="1.0"?>
       <ThermalConfiguration>
         <Platform>
           <Name>Override CPU default passive</Name>
           <ProductName>*</ProductName>
           <Preference>QUIET</Preference>
           <ThermalZones>
             <ThermalZone>
               <Type>cpu</Type>
               <TripPoints>
                 <TripPoint>
                   <Temperature>86000</Temperature>
                   <type>passive</type>
                 </TripPoint>
               </TripPoints>
             </ThermalZone>
           </ThermalZones>
         </Platform>
       </ThermalConfiguration>

       Example 2: In this configuration, we  are  controlling  backlight  when
       some  sensor  "SEN2"  reaches 60C. Here "LCD" is a standard cooling de-
       vice, which uses Linux backlight sysfs interface. "LCD_Zone" is a valid
       thermal zone in Linux thermal sysfs on  the  test  platform,  hence  we
       don't  need to provide path for sysfs for "LCD_Zone". The Linux thermal
       sysfs is already parsed and loaded by the thermald program.

       <?xml version="1.0"?>
       <ThermalConfiguration>
         <Platform>
           <Name>Change Backlight</Name>
           <ProductName>*</ProductName>
           <Preference>QUIET</Preference>
           <ThermalZones>
             <ThermalZone>
               <Type>LCD_Zone</Type>
               <TripPoints>
                 <TripPoint>
                   <SensorType>SEN2</SensorType>
                   <Temperature>60000</Temperature>
                   <type>passive</type>
                   <CoolingDevice>
                     <Type>LCD</Type>
                   </CoolingDevice>
                 </TripPoint>
               </TripPoints>
             </ThermalZone>
           </ThermalZones>
         </Platform>
       </ThermalConfiguration>

       Example 3: In this example Lenovo Thinkpad X220 and fan speed  is  con-
       trolled.  Here  a  cooling  device  "_Fan", can be controlled via sysfs
       /sys/devices/platform/thinkpad_hwmon/pwm1.   When   the    x86_pkg_temp
       reaches  45C, Fan is started with increasing speeds, if the temperature
       can't be controlled at 45C.

       <?xml version="1.0"?>
       <ThermalConfiguration>
         <Platform>
           <Name>Lenovo ThinkPad X220</Name>
           <ProductName>*</ProductName>
           <Preference>QUIET</Preference>
           <ThermalZones>
             <ThermalZone>
               <Type>x86_pkg_temp</Type>
               <TripPoints>
                 <TripPoint>
                   <SensorType>x86_pkg_temp</SensorType>
                   <Temperature>45000</Temperature>
                   <type>passive</type>
                   <ControlType>SEQUENTIAL</ControlType>
                   <CoolingDevice>
                     <index>1</index>
                     <type>_Fan</type>
                     <influence> 100 </influence>
                     <SamplingPeriod> 12 </SamplingPeriod>
                   </CoolingDevice>
                 </TripPoint>
               </TripPoints>
             </ThermalZone>
           </ThermalZones>
           <CoolingDevices>
             <CoolingDevice>
               <Type>_Fan</Type>
               <Path>/sys/devices/platform/thinkpad_hwmon/pwm1</Path>
               <MinState>0</MinState>
               <IncDecStep>30</IncDecStep>
               <ReadBack> 0 </ReadBack>
               <MaxState>255</MaxState>
               <DebouncePeriod>5</DebouncePeriod>
             </CoolingDevice>
           </CoolingDevices>
         </Platform>
       </ThermalConfiguration>

       Example 4: The following example shows how PID can be used.  Here  once
       temperature exceeds 80C, compensation is calculated using PID using 80C
       as  set  point  of  PID. The compensation depends on error from the set
       point. Here the default built in processor cooling device is used  with
       min state as 0 and max state as 10.

       <?xml version="1.0"?>
       <ThermalConfiguration>
         <Platform>
           <Name>Use PID param </Name>
           <ProductName>*</ProductName>
           <Preference>QUIET</Preference>
           <ThermalZones>
             <ThermalZone>
               <Type>x86_pkg_temp</Type>
               <TripPoints>
                 <TripPoint>
                   <SensorType>x86_pkg_temp</SensorType>
                   <Temperature>80000</Temperature>
                   <type>passive</type>
                   <ControlType>SEQUENTIAL</ControlType>
                   <CoolingDevice>
                     <type>Processor</type>
                   </CoolingDevice>
                 </TripPoint>
               </TripPoints>
             </ThermalZone>
           </ThermalZones>
           <CoolingDevices>
             <CoolingDevice>
               <Type>Processor</Type>
               <PidControl>
                 <kp>0.0002</kp>
                 <kd>0</kd>
                 <ki>0</ki>
               </PidControl>
             </CoolingDevice>
           </CoolingDevices>
         </Platform>
       </ThermalConfiguration>

       Example  5:  The  following  example  shows how to control Fan when the
       sysfs expects some string prefix. For example instead of just  write  a
       number  to  fan control sysfs, the interface requires "level " in front
       of the speed index value.

       <?xml version="1.0"?>
       <ThermalConfiguration>
         <Platform>
           <Name>Use Fan control first then CPU throttle </Name>
           <ProductName>*</ProductName>
           <Preference>QUIET</Preference>
           <ThermalZones>
             <ThermalZone>
               <Type>x86_pkg_temp</Type>
               <TripPoints>
                 <TripPoint>
                   <SensorType>x86_pkg_temp</SensorType>
                   <Temperature>80000</Temperature>
                   <type>passive</type>
                   <ControlType>SEQUENTIAL</ControlType>
                   <CoolingDevice>
                     <type>_fan_</type>
                   </CoolingDevice>
                 </TripPoint>
               </TripPoints>
             </ThermalZone>
           </ThermalZones>
           <CoolingDevices>
             <CoolingDevice>
               <Type>_fan_</Type>
               <Path>/proc/acpi/ibm/fan</Path>
               <WritePrefix>level </WritePrefix>
               <MinState>0</MinState>
               <MaxState>5</MaxState>
               <DebouncePeriod>10</DebouncePeriod>
             </CoolingDevice>
           </CoolingDevices>
         </Platform>
       </ThermalConfiguration>

       Example 6: Similar to example 5, but write different speeds at  differ-
       ent temperatures.

       <?xml version="1.0"?>
       <ThermalConfiguration>
         <Platform>
           <Name>Use Fan control first then CPU throttle </Name>
           <ProductName>*</ProductName>
           <Preference>QUIET</Preference>
           <ThermalZones>
             <ThermalZone>
               <Type>x86_pkg_temp</Type>
               <TripPoints>
                 <TripPoint>
                   <SensorType>x86_pkg_temp</SensorType>
                   <Temperature>80000</Temperature>
                   <type>passive</type>
                   <CoolingDevice>
                     <type>_fan_</type>
                     <TargetState>1</TargetState>
                   </CoolingDevice>
                 </TripPoint>
                 <TripPoint>
                   <SensorType>x86_pkg_temp</SensorType>
                   <Temperature>85000</Temperature>
                   <type>passive</type>
                   <CoolingDevice>
                     <type>_fan_</type>
                     <TargetState>2</TargetState>
                   </CoolingDevice>
                 </TripPoint>
               </TripPoints>
             </ThermalZone>
           </ThermalZones>
           <CoolingDevices>
             <CoolingDevice>
               <Type>_fan_</Type>
               <Path>/proc/acpi/ibm/fan</Path>
               <WritePrefix>level </WritePrefix>
               <MinState>0</MinState>
               <MaxState>5</MaxState>
               <DebouncePeriod>10</DebouncePeriod>
             </CoolingDevice>
           </CoolingDevices>
         </Platform>
       </ThermalConfiguration>

       Example 7: Use RAPL power limits to control.

       <?xml version="1.0"?>
       <!-- BEGIN -->
       <ThermalConfiguration>
       <Platform>
            <Name> TEST </Name>
            <ProductName>Example_RAPL_Power </ProductName>
            <Preference>QUIET</Preference>
            <PPCC>
                 <!--
                 Specify the Maximum/Minimum RAPL power limit for the
                 platform. The limits are in milli watts.
                 The step size to reduce/increase for each sampling interval
                 Time window in miili seconds.
                 -->
                 <PowerLimitIndex>0</PowerLimitIndex>
                 <PowerLimitMaximum>15000</PowerLimitMaximum>
                 <PowerLimitMinimum>2000</PowerLimitMinimum>
                 <TimeWindowMinimum>20</TimeWindowMinimum>
                 <TimeWindowMaximum>30</TimeWindowMaximum>
                 <StepSize>1000</StepSize>
            </PPCC>
            <ThermalZones>
                 <ThermalZone>
                      <Type>TestZone</Type>
                      <TripPoints>
                           <TripPoint>
                                <SensorType>SEN3</SensorType>
                                <Temperature>50000</Temperature>
                                <Type>Passive</Type>
                                <CoolingDevice>
                                     <Type>B0D4</Type>
                                     <SamplingPeriod>3</SamplingPeriod>
                                     <TargetState>2147483647</TargetState>
                                          <!--
                                          This setting means that when SEN3 reaches 50C, set the RAPL
                                          max power limit to whatever the maximum power limit of the
                                          platform.
                                          -->
                                </CoolingDevice>
                           </TripPoint>
                           <TripPoint>
                                <SensorType>SEN3</SensorType>
                                <Temperature>52000</Temperature>
                                <Type>Passive</Type>
                                <CoolingDevice>
                                     <Type>B0D4</Type>
                                     <SamplingPeriod>3</SamplingPeriod>
                                     <TargetState>8500000</TargetState>
                                          <!--
                                          This setting means that when SEN3 reaches 52C, set the RAPL
                                          max power limit to 8.5W.
                                          -->
                                </CoolingDevice>
                           </TripPoint>
                           <TripPoint>
                                <SensorType>SEN3</SensorType>
                                <Temperature>60000</Temperature>
                                <Type>Passive</Type>
                                <CoolingDevice>
                                     <Type>B0D4</Type>
                                     <SamplingPeriod>3</SamplingPeriod>
                                     <TargetState>4500000</TargetState>
                                          <!--
                                          This setting means that when SEN3 reaches 60C, set the RAPL
                                          max power limit to 4.5W.
                                          -->
                                </CoolingDevice>
                           </TripPoint>
                           <TripPoint>
                                <SensorType>SEN3</SensorType>
                                <Temperature>65000</Temperature>
                                <Type>Passive</Type>
                                <CoolingDevice>
                                     <Type>B0D4</Type>
                                     <SamplingPeriod>3</SamplingPeriod>
                                          <!--
                                          This setting means that when SEN3 reaches 65C, set the RAPL
                                          max power limit to minimum power limit for the platform.
                                          -->
                                </CoolingDevice>
                           </TripPoint>
                      </TripPoints>
                 </ThermalZone>
            </ThermalZones>
       </Platform>
       </ThermalConfiguration>

                                 Dec 18, 2018              thermal-conf.xml(5)